INVERTER DRIVE PARAMETERS

SECO - LIFTER REEL APPLICATIONS

* - denotes change from Factory setting. All other parameters are set at Factory defaults.

Param

Param

Gaston County Values

 
   

Preset

2HP

   

Password

no-00

01

01

 

Programmed constants 01 -19 can be read only

Operation Signal Selection

no-01

0000

*0100

 

Four digit binary code sets Reference, Run/Stop, Stopping Method and Output Voltage Limiter

Max Frequency

no-02

60.0

60.0

 

Sets the Max. frequency (Fmax)

Max Voltage

no-03

460.0

460.0

 

Sets the maximum voltage of the motor (Vmax)

Max Voltage Frequency

no-04

60.0

60.0

 

Sets the maximum voltage frequency (Fa)

Frequency Midpoint

no-05

1.5

1.5

 

Sets the frequency midpoint (Fb)

Voltage Midpoint

no-06

24.0

24.0

 

Sets the voltage midpoint (Vc)

Min Output Frequency

no-07

1.5

1.5

 

Sets the minimum output of drive (Fmin)

Min Output Frequency Voltage

no-08

24.0

24.0

 

Sets the minimum output frequency voltage (Vmin)

Accel Time 1

no-09

10.0

10.0

 

Sets the accelleration time Fmin to Fmax

Decel Time 1

no-10

10.0

10.0

 

Sets the decelleration time Fmax to Fmin

Accel Time 2

no-11

10.0

10.0

 

Settings for a second Accelleration time

Decel Time 2

no-12

10.0

10.0

 

Settings for a second Decelleration time

Frequency Reference 1

no-13

0.0

0.0

 

Multi step speed reference setting number 1

Frequency Reference 2

no-14

0.0

0.0

 

Multi step speed reference setting number 2

Frequency Reference 3

no-15

0.0

0.0

 

Multi step speed reference setting number 3

Frequency Reference 4

no-16

0.0

0.0

 

Multi step speed reference setting number 4

Jog Frequency Reference

no-17

0.0

0.0

 

Multi step speed reference setting number 1

Motor Protection

no-18

0000

0000

 

Binary code set for motor variable torque theermal overload protection

Motor Rated Current

no-19

1.6

*1.8

 

Motor max amps

Operation Selection 2

no-20

0000

0000

 

Set for Operation of reverse

Ouput Monitor Selection

no-21

0000

*0010

 

Monitor Output Current at terms 11 & 12

Freq Command Gain

no-22

1.00

1.00

 

Sets the External Speed frequency gain

Freq Command Bias

no-23

0.00

0.00

 

Sets the external speed frequency reference bias

Frequency Command Upper Limit

no-24

100

100

 

% of max frequency no-02 that may be used as the max setting

Frequency Command Lower Limit

no-25

0

0

 

% of max frequency no-02 that may be used as the min setting`

DC Injection Braking Current

no-26

50

50

 

Limmit of DC current level produced at stopping

DC Injection Braking Stop

no-27

0.0

0.0

 

Duration of DC Injection on ramp to stop

DC Injection Braking Start

no-28

0.0

0.0

 

Duration of DC Injection on ramp to start

Auto Torque Boost Gain

no-29

1.0

1.0

 

Torque compensation for Drive to Motor performance matching

Stall Prevention Level Accel

no-30

170

170

 

% rated output. adjusts frequency to load to prevent motor stall

Stall Prevention Level at Speed

no-31

160

160

 

% rated output. determiness output current level while running at speed

Multi Function Input Term 3

no-32

13

13

 

Fault Reset input

Multi Function Input Term 4

no-33

01

*10

 

Speed search from set Frequency

Multi Function Input Term 5

no-34

03

03

 

Multi Step Speed Reference

Multi Function Analog Input

no-35

00

00

 

Optional PCB not Present

Multi Function Output Relay

no-36

05

05

 

Fault Contact Output Terminal FLT-A,B,C

Multi Function Output Term 13

no-37

00

00

 

Running Output Terminal 13

Multi Function Output Relay

no-38

01

01

 

Speed at set Frequency Output Terminal 14

Frequency Detection Level

no-39

0.0

0.0

 

Frequency level for Multi Function Output terminal change

Over Torque Detect Function

no-40

0000

*0101

 

Binary coded function for over torque detection disabled

Over Torque Detection Level

no-41

160

*150

 

Over torque detection level reference

Over Torque Detection Time

no-42

0.1

*3.0

 

Over torque detection level time duration before alarm

Carrier Frequency

no-43

4

4

 

10 khz operating noise level allowed

-------------

no-44

--

--

 

not used

Analog Monitor Gain

no-45

1.00

1.00

 

Gain of output signal no-21

Mom Power Loss Function

no-46

0000

0000

 

Momentary power loss ride thru disabled

Auto Restart Attempts

no-47

0

0

 

No auto reset attempt is allowed

Fault Record

no-48

n/a

n/a

 

Displays last fault

PROM #

no-49

n/a

n/a

 

Displays Prom code number

Prohibited Frequency

no-50

0.0

0.0

 

Programmed frequency to eliminate for resonant vibration problems

Prohibited Frequency Deadband

no-51

1.0

1.0

 

Width of deadband above and below prohibited frequency of no-50

---------------

no-52 - no-59

--

--

 

Not Used

2.0 Notes

When used as Lifter Reel drives with two wire control, a wire jumper is required from terminal 1 to terminal 4. This will insure drive can start into a spinning motor if preset no-33 is set as shown above.

 

Copyright © 2003 by Gaston County Dyeing Machine Company.  All rights reserved. 