Param |
Param |
Gaston County Values |
|
|
|
Preset |
2HP |
|
|
Password |
no-00 |
01 |
01 |
|
Programmed constants 01 -19 can be read only |
Operation Signal Selection |
no-01 |
0000 |
*0100 |
|
Four digit binary code sets Reference, Run/Stop, Stopping Method and
Output Voltage Limiter |
Max Frequency |
no-02 |
60.0 |
60.0 |
|
Sets the Max. frequency (Fmax) |
Max Voltage |
no-03 |
460.0 |
460.0 |
|
Sets the maximum voltage of the motor (Vmax) |
Max Voltage Frequency |
no-04 |
60.0 |
60.0 |
|
Sets the maximum voltage frequency (Fa) |
Frequency Midpoint |
no-05 |
1.5 |
1.5 |
|
Sets the frequency midpoint (Fb) |
Voltage Midpoint |
no-06 |
24.0 |
24.0 |
|
Sets the voltage midpoint (Vc) |
Min Output Frequency |
no-07 |
1.5 |
1.5 |
|
Sets the minimum output of drive (Fmin) |
Min Output Frequency Voltage |
no-08 |
24.0 |
24.0 |
|
Sets the minimum output frequency voltage (Vmin) |
Accel Time 1 |
no-09 |
10.0 |
10.0 |
|
Sets the accelleration time Fmin to Fmax |
Decel Time 1 |
no-10 |
10.0 |
10.0 |
|
Sets the decelleration time Fmax to Fmin |
Accel Time 2 |
no-11 |
10.0 |
10.0 |
|
Settings for a second Accelleration time |
Decel Time 2 |
no-12 |
10.0 |
10.0 |
|
Settings for a second Decelleration time |
Frequency Reference 1 |
no-13 |
0.0 |
0.0 |
|
Multi step speed reference setting number 1 |
Frequency Reference 2 |
no-14 |
0.0 |
0.0 |
|
Multi step speed reference setting number 2 |
Frequency Reference 3 |
no-15 |
0.0 |
0.0 |
|
Multi step speed reference setting number 3 |
Frequency Reference 4 |
no-16 |
0.0 |
0.0 |
|
Multi step speed reference setting number 4 |
Jog Frequency Reference |
no-17 |
0.0 |
0.0 |
|
Multi step speed reference setting number 1 |
Motor Protection |
no-18 |
0000 |
0000 |
|
Binary code set for motor variable torque theermal overload protection |
Motor Rated Current |
no-19 |
1.6 |
*1.8 |
|
Motor max amps |
Operation Selection 2 |
no-20 |
0000 |
0000 |
|
Set for Operation of reverse |
Ouput Monitor Selection |
no-21 |
0000 |
*0010 |
|
Monitor Output Current at terms 11 & 12 |
Freq Command Gain |
no-22 |
1.00 |
1.00 |
|
Sets the External Speed frequency gain |
Freq Command Bias |
no-23 |
0.00 |
0.00 |
|
Sets the external speed frequency reference bias |
Frequency Command Upper Limit |
no-24 |
100 |
100 |
|
% of max frequency no-02 that may be used as the max setting |
Frequency Command Lower Limit |
no-25 |
0 |
0 |
|
% of max frequency no-02 that may be used as the min setting` |
DC Injection Braking Current |
no-26 |
50 |
50 |
|
Limmit of DC current level produced at stopping |
DC Injection Braking Stop |
no-27 |
0.0 |
0.0 |
|
Duration of DC Injection on ramp to stop |
DC Injection Braking Start |
no-28 |
0.0 |
0.0 |
|
Duration of DC Injection on ramp to start |
Auto Torque Boost Gain |
no-29 |
1.0 |
1.0 |
|
Torque compensation for Drive to Motor performance matching |
Stall Prevention Level Accel |
no-30 |
170 |
170 |
|
% rated output. adjusts frequency to load to prevent motor stall |
Stall Prevention Level at Speed |
no-31 |
160 |
160 |
|
% rated output. determiness output current level while running at speed |
Multi Function Input Term 3 |
no-32 |
13 |
13 |
|
Fault Reset input |
Multi Function Input Term 4 |
no-33 |
01 |
*10 |
|
Speed search from set Frequency |
Multi Function Input Term 5 |
no-34 |
03 |
03 |
|
Multi Step Speed Reference |
Multi Function Analog Input |
no-35 |
00 |
00 |
|
Optional PCB not Present |
Multi Function Output Relay |
no-36 |
05 |
05 |
|
Fault Contact Output Terminal FLT-A,B,C |
Multi Function Output Term 13 |
no-37 |
00 |
00 |
|
Running Output Terminal 13 |
Multi Function Output Relay |
no-38 |
01 |
01 |
|
Speed at set Frequency Output Terminal 14 |
Frequency Detection Level |
no-39 |
0.0 |
0.0 |
|
Frequency level for Multi Function Output terminal change |
Over Torque Detect Function |
no-40 |
0000 |
*0101 |
|
Binary coded function for over torque detection disabled |
Over Torque Detection Level |
no-41 |
160 |
*150 |
|
Over torque detection level reference |
Over Torque Detection Time |
no-42 |
0.1 |
*3.0 |
|
Over torque detection level time duration before alarm |
Carrier Frequency |
no-43 |
4 |
4 |
|
10 khz operating noise level allowed |
------------- |
no-44 |
-- |
-- |
|
not used |
Analog Monitor Gain |
no-45 |
1.00 |
1.00 |
|
Gain of output signal no-21 |
Mom Power Loss Function |
no-46 |
0000 |
0000 |
|
Momentary power loss ride thru disabled |
Auto Restart Attempts |
no-47 |
0 |
0 |
|
No auto reset attempt is allowed |
Fault Record |
no-48 |
n/a |
n/a |
|
Displays last fault |
PROM # |
no-49 |
n/a |
n/a |
|
Displays Prom code number |
Prohibited Frequency |
no-50 |
0.0 |
0.0 |
|
Programmed frequency to eliminate for resonant vibration problems |
Prohibited Frequency Deadband |
no-51 |
1.0 |
1.0 |
|
Width of deadband above and below prohibited frequency of no-50 |
--------------- |
no-52 - no-59 |
-- |
-- |
|
Not Used |